9,319 research outputs found

    Phase-stepping fiber-optic projected fringe system for surface topography measurements

    Get PDF
    A projected fringe interferometer for measuring the topography of an object is presented. The interferometer periodically steps the phase angle between a pair of light beams emanating from a common source. The steps are pi/2 radians (90 deg) apart, and at each step a video image of the fringes is recorded and stored. Photodetectors measure either the phase and theta of the beams or 2(theta). Either of the measures can be used to control one of the light beams so that the 90 deg theta is accurately maintained. A camera, a computer, a phase controller, and a phase modulator established closed-loop control of theta. Measuring the phase map of a flat surface establishes a calibration reference

    Fiber-optic projected-fringe digital interferometry

    Get PDF
    A phase-stepped projected-fringe interferometer was developed which uses a closed-loop fiber-optic phase-control system to make very accurate surface profile measurements. The closed-loop phase-control system greatly reduces phase-stepping error, which is frequently the dominant source of error in digital interferometers. Two beams emitted from a fiber-optic coupler are combined to form an interference fringe pattern on a diffusely reflecting object. Reflections off of the fibers' output faces are used to create a phase-indicating signal for the closed-loop optical phase controller. The controller steps the phase difference between the two beams by pi/2 radians in order to determine the object's surface profile using a solid-state camera and a computer. The system combines the ease of alignment and automated data reduction of phase-stepping projected-fringe interferometry with the greatly improved phase-stepping accuracy of our closed-loop phase-controller. The system is demonstrated by measuring the profile of a plate containing several convex surfaces whose heights range from 15 to 25 micron high

    Active phase compensation system for fiber optic holography

    Get PDF
    Fiber optic delivery systems promise to extend the application of holography to severe environments by simplifying test configurations and permitting the laser to be remotely placed in a more benign location. However, the introduction of optical fiber leads to phase stability problems. Environmental effects cause the pathlengths of the fibers to change randomly, preventing the formation of stationary interference patterns which are required for holography. An active phase control system has been designed and used with an all-fiber optical system to stabilize the phase difference between light emitted from two fibers, and to step the phase difference by 90 deg without applying any constraints on the placement of the fibers. The accuracy of the phase steps is shown to be better than 0.02 deg., and a stable phase difference can be maintained for 30 min. This system can be applied to both conventional and electro-optic holography, as well as to any system where the maintenance of an accurate phase difference between two coherent beams is required

    Speckle interferometry using fiber optic phase stepping

    Get PDF
    A system employing closed-loop phase-stepping is used to measure the out-of-plane deformation of a diffusely reflecting object. Optical fibers are used to provide reference and object beam illumination for a standard two-beam speckle interferometer, providing set-up flexibility and ease of alignment. Piezoelectric fiber-stretchers and a phase-measurement/servo system are used to provide highly accurate phase steps. Intensity data is captured with a charge-injection-device camera, and is converted into a phase map using a desktop computer. The closed-loop phase-stepping system provides 90 deg phase steps which are accurate to 0.02 deg, greatly improving this system relative to open-loop interferometers. The system is demonstrated on a speckle interferometer, measuring the rigid-body translation of a diffusely reflecting object with an accuracy + or - 10 deg, or roughly + or - 15 nanometers. This accuracy is achieved without the use of a pneumatically mounted optics table

    Future of smart cardiovascular implants

    Get PDF
    Cardiovascular disease remains the leading cause of death in Western society. Recent technological advances have opened the opportunity of developing new and innovative smart stent devices that have advanced electrical properties that can improve diagnosis and even treatment of previously intractable conditions, such as central line access failure, atherosclerosis and reporting on vascular grafts for renal dialysis. Here we review the latest advances in the field of cardiovascular medical implants, providing a broad overview of the application of their use in the context of cardiovascular disease rather than an in-depth analysis of the current state of the art. We cover their powering, communication and the challenges faced in their fabrication. We focus specifically on those devices required to maintain vascular access such as ones used to treat arterial disease, a major source of heart attacks and strokes. We look forward to advances in these technologies in the future and their implementation to improve the human condition

    Laser interferometric measurement of ion electrode shape and charge exchange erosion

    Get PDF
    A projected fringe profilometry system was applied to surface contour measurements of an accelerator electrode from an ion thrustor. The system permitted noncontact, nondestructive evaluation of the fine and gross structure of the electrode. A 3-D surface map of a dished electrode was generated without altering the electrode surface. The same system was used to examine charge exchange erosion pits near the periphery of the electrode to determine the depth, location, and volume of material lost. This electro-optical measurement system allowed rapid, nondestructive, digital data acquisition coupled with automated computer data processing. In addition, variable sensitivity allowed both coarse and fine measurements of objects having various surface finishes

    Lin28A induces energetic switching to glycolytic metabolism in human embryonic kidney cells

    Get PDF
    Background: Loss of a cell’s capacity to generate sufficient energy for cellular functions is a key hallmark of the ageing process and ultimately leads to a variety of important age-related pathologies such as cancer, Parkinson’s disease and atherosclerosis. Regenerative medicine has sought to reverse these pathologies by reprogramming somatic cells to a more juvenile energetic state using a variety of stem cell factors. One of these factors, Lin28, is considered a candidate for modification in the reprogramming of cellular energetics to ameliorate the ageing process while retaining cell phenotype. Results: Over-expression of Lin28A resulted in key changes to cellular metabolism not observed in wild-type controls. Extracellular pH flux analysis indicated that Lin28A over expression significantly increased the rate of glycolysis, whilst high resolution oxygen respirometry demonstrated a reduced oxygen consumption. Western blot and real-time PCR analysis identified Hexokinase II as one of the key modulators of glycolysis in these cells which was further confirmed by increased glucose transport. A metabolic switching effect was further emphasised by Western blot analysis where the oxygen consuming mitochondrial complex IV was significantly reduced after Lin28A over expression. Conclusions: Results from this study confirm that Lin28A expression promotes metabolic switching to a phenotype that relies predominantly on glycolysis as an energy source, while compromising oxidative phosphorylation. Mechanisms to augment regulated Lin28A in age related pathologies that are characterised by mitochondria dysfunction or in differentiated and aged post-mitotic cells is the future goal of this work

    Performance characteristics of an isolated coannular plug nozzle at transonic speeds

    Get PDF
    The Langley 16-Foot Transonic Tunnel was used to evaluate the performance characteristics of a coannular plug nozzle at static conditions (Mach number of 0) and at Mach numbers from 0.65 to 1.20. Jet total pressure ratio was varied from 1.0 (jet off) to 10.0. Thirty-seven configurations generated by the combination of three geometric variables - plug angle, shroud boattail length (fixed exit radius), and shroud extension length - were tested

    Battery and Fuel Cell Development Goals for the Lunar Surface and Lander

    Get PDF
    NASA is planning a return to the moon and requires advances in energy storage technology for its planned lunar lander and lunar outpost. This presentation describes NASA s overall mission goals and technical goals for batteries and fuel cells to support the mission. Goals are given for secondary batteries for the lander s ascent stage and suits for extravehicular activity on the lunar surface, and for fuel cells for the lander s descent stage and regenerative fuel cells for outpost power. An overall approach to meeting these goals is also presented

    An image of communication: theories of imaging in cognitive psychology

    Get PDF
    Thesis (M.A.)--University of Oklahoma, 1994.Includes bibliographical references (leaves 35-36)In an empirical study, visual breakpoints were created from a motion video presentation. These were then used, along with the original motion video presentation , in a memory test experiment testing for recall of abstract information contained in the presentation narrative. Twenty subjects, undergraduate psychology students, marked the breakpoints. Next, thirteen subjects viewed a the presentation which contained only the still breakpoint frames. Fourteen students viewed the original, motion video presentation. Each group was given a recall test on the facts in the presentation narrative immediately after exposure and 48 hours later. TI1e breakpoints were graphed and analyzed for characteristics relevant to the visual media's tradition of the decisive moment. In addition, it was proposed four types of breakpoints could be identified. The memory test yielded no significant results. The hypothesis, that breakpoint subjects would perform better than motion subjects in a memory test remains unsupported
    • …
    corecore